The WPM-ADL-0.5KN is a horizontal pull tester with a digital force gauge, built for crimp and weld connections on cable. Capacity is 500 N, with 1000 N available as an option, at 0.01 N resolution and ±0.5% accuracy. The gauge measures 115 x 180 x 30 mm and runs on a rechargeable battery charged from 220 V AC in 4 to 6 hours.
A crimp that has to be signed off needs a number, not a needle position. The sample is held between the clamp block on the left of the bed and the three-pin wire grip, the crank with the ball handle draws the sliding carriage away, and the gauge sits in the load path and holds the peak. Readings appear on the LCD, are entered on the keypad, and the ports at the end of the gauge take the data out to a PC. Allowable overload is 150%, so a pull that runs past 500 N does not end the gauge.
Against the WPM-490N the difference is resolution and record: the 490N reads 0 to 490 N on a dial, this unit resolves 0.01 N at ±0.5% and outputs the value. Where a series of pulls has to be logged against a crimp specification, this is the instrument; where a quick pass or fail at the bench is enough, the dial tester is simpler. Loads above hand-crank range go to the WPM-5000A motorised stand, which pulls at a set 15 to 240 mm/min.
Key Features
1. 500 N capacity, 1000 N optional, with 0.01 N resolution and ±0.5% accuracy.
2. 150% allowable overload, so a test that overshoots 500 N does not end the gauge.
3. Three-pin wire grip and a toggle clamp block hold the terminal and the wire end in line with the pull axis.
4. Crank with a ball handle drives the carriage by hand, and the gauge holds the peak for reading after release.
5. LCD and keypad on the gauge, with data ports at the end of the housing for transfer to a PC.
6. Battery powered with 220 V AC charging over 4-6 hours, so the tester can be used at a bench or at incoming inspection.
Technical Specifications
| Parameter | Specification |
|---|
| Model | WPM-ADL-0.5KN |
|---|
| Machine type | Horizontal terminal pull force tester |
|---|
| Force range | 500 N (1000 N optional) |
|---|
| Resolution | 0.01 N |
|---|
| Accuracy | ±0.5% |
|---|
| Allowable overload | 150% |
|---|
| Power supply | Battery, 220 V AC charging 4-6 hours |
|---|
| Ambient temperature | 0-60 °C |
|---|
| Ambient humidity | Below 80% |
|---|
| Gauge dimensions | 115 x 180 x 30 mm |
|---|
Applications
— Crimp pull test: terminal-to-wire pull force recorded against a crimp specification.
— Ultrasonic weld and splice: joint strength on harness splices.
— Connector retention: contact retention in housings and connector shells.
— Solder joint pull: lead-to-pad joints on connector boards checked to a set force.
— Incoming goods inspection: batch sampling of purchased crimped leads with the values logged.